San Francisco inspections · San Francisco
AJ'S BAR
1250 MARKET ST STE 101, San Francisco · BARS/TAVERNS W/O FOOD PREP
Pass
No violations.
8 inspections since 2024
- Pass
- PassMar 14, 2025New Ownership (I)
- PassMar 13, 2025
- PassMar 7, 2025
- PassDec 9, 2024
3 earlier inspections
PassApr 8, 2024
- All new and used equipment and utensils shall be certified or classified for sanitation by an American National Standards Institute (ANSI) accredited certification program, e.g. NSF, ETL Sanitation, UL Sanitation, CSA Sanitation.
- Adequate and suitable space shall be provided for the storage of food, on approved shelving with a minimum of 6 inch clearance from the floor.
- Pressurized warm water shall be provided by all handwashing sinks for a minimum of 15 seconds through a mixing valve or combination faucet. At handwashing sinks where the water temperature provided is not readily adjustable at the faucets, warm water between 100°F-108°F shall be provided.
- The water supply shall be from a water system approved by the local enforcement agency.
- Provide minimum 6 inches high side splashguard(s) with rounded corners.
- Wall and ceiling finish shall be smooth, durable, easily cleanable, and non-absorbent in all areas where there is food service or preparation, open food storage, warewashing, janitorial service, trash storage, and employee restrooms.
- Floor surfaces shall be coved at the juncture of the floor and wall with a 3/8 inch minimum radius coving and shall extend up the wall at least 4 inches.
- Sink compartments shall be large enough to accommodate the immersion of the largest equipment and utensils.
- Multiuse food -contact surfaces shall be smooth, free of breaks, open seams, cracks, chips, inclusions, pits, and similar imperfections, free of sharp internal angles, corners, and crevices, finished to have smooth welds and joints.
- Equipment for holding cold food shall be sufficient in number and capacity to ensure proper food temperature control.
- Equipment that discharges liquid waste, e.g. food preparation sinks, dishwashing machines, steam tables, ice machines and bins, espresso machines, walk-in refrigeration units, shall have approved indirect drainage through an air gap into a floor sink or other approved receiving vessel.
- PassFeb 27, 2024
PassFeb 15, 2024
- Lockers or other suitable facilities shall be located in a designated room or area where contamination of food, equipment, utensils, linens, and single-use articles cannot occur.
- A permanent food facility shall provide clean toilet facilities in good repair for use by employees.
- Provide a floor plan showing the path-of-travel to the refuse storage area.
- Equipment for holding cold food shall be sufficient in number and capacity to ensure proper food temperature control.
- The floor finish shall be smooth, durable, easily cleanable, and non-absorbent in all areas where there is food service or preparation, open food storage, warewashing, janitorial service, trash storage, and employee restrooms.
- Floor surfaces shall be coved at the juncture of the floor and wall with a 3/8 inch minimum radius coving and shall extend up the wall at least 4 inches.
- Provide a designated area for refuse, recyclables, and compost separate from food, equipment, and utensils.
- The water supply shall be from a water system approved by the local enforcement agency.
- All permanent food facilities that wash, rinse, soak, thaw, or similarly prepare foods shall be provided with a food preparation sink with a single integral drainboard. The food preparation sink shall have a minimum dimension of 18"x18"x12" (LxWxD) with an integral drainboard at least 18"x18" (LxW).
- All new and used equipment and utensils shall be certified or classified for sanitation by an American National Standards Institute (ANSI) accredited certification program, e.g. NSF, ETL Sanitation, UL Sanitation, CSA Sanitation.
- At least one curbed cleaning facility or janitorial sink equipped with hot and cold water and a drain shall be provided and conveniently located.
- Floor drains shall be installed in floors that are water-flushed for cleaning and in areas where pressure spray methods for cleaning equipment are used.
- Hand sinks shall be sufficient in number and conveniently located so as to be accessible at all times.
- Multiuse food -contact surfaces shall be smooth, free of breaks, open seams, cracks, chips, inclusions, pits, and similar imperfections, free of sharp internal angles, corners, and crevices, finished to have smooth welds and joints.
- Wall and ceiling finish shall be smooth, durable, easily cleanable, and non-absorbent in all areas where there is food service or preparation, open food storage, warewashing, janitorial service, trash storage, and employee restrooms.
- Provide a 3-compartment sink with two integral metal drainboards for manually washing, rinsing, and sanitizing equipment and utensils.
- Pressurized warm water shall be provided by all handwashing sinks for a minimum of 15 seconds through a mixing valve or combination faucet. At handwashing sinks where the water temperature provided is not readily adjustable at the faucets, warm water between 100°F-108°F shall be provided.
- Adequate and suitable space shall be provided for the storage of food, on approved shelving with a minimum of 6 inch clearance from the floor.
Check before you go. Every San Francisco restaurant on one map. Free, no account.
DataSF · Open Data Commons Public Domain Dedication and License · ID 06734955 · records through Nov 25, 2026
A re-inspection brings a new placard, so the color on the door can change. ForkFax is not affiliated with the city. How grades work · Report a problem